Guidelines for the acceptable ranges of flow velocity for various fluids found in a sugar factory
Maximal velocity in pipes
Water |
m/s |
ft/s |
Tap water (low noise) |
0.5 - 0.7 |
1.6 -8.2 |
Tap water |
1.0 - 2.5 |
3.3 - 8.2 |
Cooling water |
1.5 - 2.5 |
4.9 - 8.2 |
Boiler feed water. suction |
0.5 - 1.0 |
1.6 - 3.3 |
Boiler feed water. discharge |
1.5 - 2.5 |
4.9 - 8.2 |
Condensate |
1.0 - 2.0 |
3.3 - 6.5 |
Heating circulation |
1.0 - 3.0 |
3.3 - 9.8 |
Steam |
m/s |
ft/s |
Saturated Steam. high pressure |
25 - 40 |
82 - 131 |
Saturated Steam. in special cases |
- 60 |
- 197 |
Saturated Steam. medium and low pressure |
30-40 |
99 - 131 |
Saturated Steam. at peak load |
- 50 |
- 164 |
Steam / Water emulsion |
- 25 |
- 82 |
Oil |
m/s |
ft/s |
Suction lines for pumps |
- 0.5 |
-1.6 |
Suction lines for pump (low pressure) |
0.1 - 0.2 |
0.3 - 0.65 |
Discharge line for booster pump |
1.0 - 2.0 |
3.3 - 6.5 |
Discharge line for burner pump |
- 1.0 |
- 3.3 |
Air |
m/s |
ft/s |
Combustion air ducts |
12 - 20 |
40 - 66 |
Air inlet to boiler room |
1 - 3 |
3.3 - 9.8 |
Warm air for house heating |
0.8 - 1.0 |
2.6 - 3.3 |
Vacuum cleaning pipe |
8 - 15 |
26 - 49 |
Compressed air pipe |
20 - 30 |
66 - 98 |
Ventilation ducts (hospitals) |
1.8 - 4 |
5.9 - 13 |
Ventilation ducts (office buildings) |
2.0 - 4.5 |
6.5 - 15 |
Exhaust gas |
m/s |
ft/s |
Ducts at minimum load |
- 4.0 |
- 13 |
Stack at minimum load |
- 5.0 |
- 16 |
Boiler with one-step burner (on - off) |
5.0 - 8.0 |
16 - 26 |
Boiler with two-step burner (high - low) |
10 - 15 |
31 - 49 |
Boiler with modulating burner (3:1) |
15 - 25 |
49 - 82 |
To keep the surface free from soot the velocity should always exceed |
3.0 - 4.0 |
9.8 - 13 |